PVC Surface Wiring. These are rated at 90C rather than 70C for 6181Y PVC insulated cables and therefore have a higher current carrying capacity for an equivalent size of cable. For use in light industrial and domestic applications where the risk of mechanical damage is low. They may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Where a conductor operates at a temperature exceeding 70C it shall be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature .
Min temperature for installation is +5gegC
PVC Surface Wiring. Often referred to as 'double insulated cable'. For use in light industrial and domestic applications where the risk of mechanical damage is low. They may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction
Plain copper conductor, single core, PVC insulated and PVC sheathed
Operating Temperature
-15degC to + 70degC
Minimum Bending Radius
3x 1.0sq to 16sq
4x 25sq to 35sq
Core Identification
Bn or Be
Lengths
100m 1.0 1.5
50/100m 16 - 35
Special lengths available on request.
PVC Surface Wiring. For use in light industrial and domestic applications where the risk of mechanical damage is low. It may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction
Solid plain copper conductors, single core, PVC insulated, core laid flat with a non insulated circuit protective conductor (cpc), PVC sheath.
Low Smoke Zero Halogen Surface Wiring. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. For use in light industrial and domestic applications where the risk of mechanical damage is low. It may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction
Plain copper conductors, XLPE insulation, cores laid flat with a non insulated circuit protective conductor (cpc), LSZH sheath.
Operating Temperature
-15degC to +90degC
Minimum Bending Radius
3x 1sqmm to 2.5sq 2 core
4x 4sqmm to16sqmm 2 core
4x 1sqmm to 10sqmm 3core
6x 16sq 3 core.
Core Identification
2 core Bn, Be
3 core Bn, Bk, Gy.
Lengths
100/500m 1.5 - 6.0
100m 10.0 - 16.0
100m 6243B 1.5
Sheath Colour
White
Manufacturing Standard
BS7211 Table 5
Fire Tests
N/A
Emissions and Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265 (IEC 60332) Flame Propagation
Special Notes
Where a conductor operates at a temperature exceeding 70C it shall be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
Min temperature for installation is +5degC.
PVC Surface Wiring. For use in light industrial and domestic applications where the risk of mechanical damage is low. It may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction
Plain copper conductors, PVC insulated, cores laid flat with a non insulated circuit protective concuctor (cpc), PVC sheath.
Operating Temperature
-15degC to +70degC
Minimum Bending Radius
3x 1 to 1.5sq 2 core
4x 2.5 to 16sq 2 core
4x 1 to 6sq 3 core
6x 10 to 16sq 3 core