AEI Cables - Signalling - LUL

logo

Login Help

Please enter your email address that you registered with. We will email you your password so you can sign in.

Your email and password are case sensitive.

* denotes a mandatory field.

Member Login

Update my password

Lost Login

Not a member yet?

Update my profile

Signalling - LUL

Product Datasheets and Approvals

Signalling - LULPrint summary for selected product(s)
Print
Compare two selected products
Compare
G7250 Type D1
Datasheet
Voltage Rating 650/1100 volts
Description Single core signalling cables
Construction Singlcore tinned copper solid or stranded conductor, LFH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 2x cable diameter <= 10mm
3x cable diameter 10 - 25mm
6x cable diameter >25mm
Core Identification Black
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7250 Type D2
Datasheet
Voltage Rating 650/1100 volts
Description Twin and multicore screened signalling cables
Construction Twin and multicore tinned copper solid or stranded conductor, insulated, cores laid up, aluminium taped spiral wire screened, sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black numbered
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7250 Type E1
Datasheet
Voltage Rating 650/1100 volts
Description Flexible singlecore signalling cables
Construction Singlcore tinned copper flexible conductor, LFH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 2xcable diameter <= 10mm
3xcable diameter 10 - 25mm
6xcable diameter >25mm
Core Identification Black
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7250 Type E2
Datasheet
Voltage Rating 650/1100 volts
Description Flexible twin and multicore screened signalling cables
Construction Twin and multicore tinned copper flexible conductor, insulated, cores laid up, aluminium taped spiral wire screened, sheathed.
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black numbered
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7622
Voltage Rating 110 volts
Description Multi-pair trackside communications with moisture barrier.
Construction Solid tinned copper wire, cellular PE insulation, cores laid up, aluminiumPETP moisture barrier tape, LSZH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Sheath Colour Violet
Manufacturing Standard G7622
Code of Practice/
Guide to Use
E4156 Part 1
S1121
G7624
Voltage Rating 750 volts
Description Track side twisted screened pair signalling cables
Construction Tinned copper strand, insulated, paired, screened, sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Blue/white
Sheath Colour Black
Manufacturing Standard G7624
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE1047 Types 1&3
LUL
Datasheet
Voltage Rating 600/1000 volts
Description PVC railway signalling cable for use in trackside bracket runs
Construction Solid wire tinned copper conductor, PVC insulated, spiral wound concentric conductor, PVC insulated, tinned copper wire screen (type 3 only), 1, 3, 7, 19 pairs laid up, PVC sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black with numbers
Sheath Colour Red
Manufacturing Standard SE1047
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE1047 Types 2&4
LUL
Datasheet
Voltage Rating 600/1000 volts
Description LSC railway signalling cables for use in trackside bracket runs
Construction Solid wire tinned copper conductor, LSZH insulated, spiral wound concentric conductor, LSZH insulated, tinned copper wire screen (type 4 only), 1, 3, 7, 19 pairs laid up, LSZH sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black with numbers
Sheath Colour Red
Manufacturing Standard SE1047
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE1093
Datasheet
Voltage Rating 600/1000 volts
Description Single core cable for use as replacement wire in railway signalling applications in trackside cases, enclosures and equipment rooms.
Construction Stranded tinned copper wire, EPR insulated, LFH sheathed
Operating Temperature -15C to +90C
Minimum Bending Radius 2x cable diameter
Core Identification White
Sheath Colour 0.5sqmm Violet
1.0sqmm Red
Manufacturing Standard MR-SE-1093
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
2-01001-002
SE330
Datasheet
Voltage Rating 600/1000 volts
Description 10 core screened Track Crossing Signalling Cable for connection to track mounted signals, points and trainstops.
Construction 10 core solid wire tinned copper conductor, EPR insulated, tinned copper screen, LFH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Numbered
Sheath Colour Black
Manufacturing Standard SSL-SE-0330
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE527
Datasheet
Voltage Rating 250 volts
Description Screened signalling circuits for use in crossing tracks
Construction Central single solid tinned conductor, EPR insulated, concentric spiral wound conductor, EPR insulation, tinned copper screen, 3 core or 5 core with telephone wires laid up and sheathed.
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification 3 core Rd, We, Bk
5 core Rd, We, Bk, Be, Gn
Sheath Colour Black
Manufacturing Standard SSL SE-0527
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE64
Description Tunnel Telephone Wire
Construction Tinned phosphor bronze wire
Manufacturing Standard SE64
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE774
Datasheet
Voltage Rating 700 volts
Description Singlecore cables for equipment room signalling power supplies and earthing
Construction Stranded tinned copper conductors, LFH insulation
Operating Temperature -15C to +85C
Minimum Bending Radius 1 to 16sqmm 2 x cable diameter
35sqmm 3 x cable diameter
Core Identification N/A
Sheath Colour Bk, Yw or Gn/Yw
Manufacturing Standard SSL-SE-0774
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE966
Voltage Rating 120 volts
Description Multipair screened cable for use with data transmission systems. Suitable for use in equipment rooms, tunnels and frieze runs behind station platform walls
Construction Stranded tinned copper conductors, PE insulation, screen, sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification 1 pair Bk/We
3 pair Bk/We, Bk/Rd, Bk/Gn
5 pair Bk/We, Bk/Rd, Bk/Gn, Bk/Be, Bk/Yw
Sheath Colour Grey
Manufacturing Standard SE966
Code of Practice/
Guide to Use
E4156 Part 1
S1121
T0504 (formerly SE902)
Datasheet
Voltage Rating 3000 volts
Description Singlecore cables for use in d.c. traction indication circuits and rail connection circuits
Construction Stranded tinned copper conductors, LFH insulation
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black or black with yellow stripe
Manufacturing Standard T0504 (formerly SE902)
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.