AEI Cables - Rolling Stock - LUL

logo

Login Help

Please enter your email address that you registered with. We will email you your password so you can sign in.

Your email and password are case sensitive.

* denotes a mandatory field.

Member Login

Update my password

Lost Login

Not a member yet?

Update my profile

Rolling Stock - LUL

Product Datasheets and Approvals

Rolling Stock - LULPrint summary for selected product(s)
Print
Compare two selected products
Compare
RSE/STD/024 Pt 6 Type I
LUL
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description Reduced wall single core cable for use in rolling stock.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type I
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type II
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Standard wall single core cable for use in rolling stock.
Construction Flexible tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type II
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type III
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Enhanced wall single core cable for use in rolling stock.
Construction Flexible tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type III
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type IV
LUL
Datasheet
3D Model
Voltage Rating 30/50 volts
Description Reduced wall single core cable for use in rolling stock.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Normally violet
yellow for safety circuits
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type IV
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type IX
LUL
Datasheet
Voltage Rating 30/50 volts
Description Reduced wall pair and multipair cable with standard sheath for use in rolling stock.
Construction Type IV cores (stranded tinned copper conductors, LFH insulation), cores twinned, individually screened with tinned copper drain wire, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Blue and brown
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type IX
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type V
LUL
Datasheet
3D Model
Voltage Rating 30/50 volts
Description Standard wall single core cable for use in rolling stock.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Normally violet
yellow for safety circuits
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type V
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type VI
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Standard wall multicore cable with enhanced sheath for use in rolling stock.
Construction Type II cores (flexible tinned copper conductors, LFH insulation), cores layed up, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 3x D if D is <10mm dia
4x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour Black with yellow stripe
Manufacturing Standard RSE/STD/024 Pt 6 Type VI
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type VII
LUL
Datasheet
Voltage Rating 30/50 volts
Description Standard wall multicore cable with enhanced sheath for use in rolling stock.
Construction Type V cores (flexible tinned copper conductors, LFH insulation), cores layed up, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 3x D if D is <10mm dia
4x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Normally violet
yellow for safety circuits
Lengths Cut lengths on request.
Sheath Colour Black with yellow stripe
Manufacturing Standard RSE/STD/024 Pt 6 Type VII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type VIII
LUL
Datasheet
Voltage Rating 30/50 volts
Description Standard wall pair and multipair cable with standard or enhanced sheath for use in rolling stock.
Construction Type V cores (flexible tinned copper conductors, LFH insulation), cores twinned, individually screened with tinned copper drain wire, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Blue and brown
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type VIII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type XI
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Reduced wall pair and multipair cable with standard sheath for use in rolling stock.
Construction Type I cores (stranded tinned copper conductors, LFH insulation), cores twinned, individually screened with tinned copper drain wire, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Red and white
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type XI
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type XII
LUL
Datasheet
3D Model
Voltage Rating 300/500 volts
Description Standard wall single core cable for use in rolling stock.
Construction Flexible tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Green
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type XII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type XIII
LUL
Datasheet
Voltage Rating 300/500 volts
Description Standard wall multicore cable with enhanced sheath for use in rolling stock.
Construction Type XII cores (flexible tinned copper conductors, LFH insulation), cores layed up, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 3x D if D is <10mm dia
4x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Green
Lengths Cut lengths on request.
Sheath Colour B+K12lack with yellow stripe
Manufacturing Standard RSE/STD/024 Pt 6 Type XIII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.