AEI Cables - Rolling Stock - EN

logo

Login Help

Please enter your email address that you registered with. We will email you your password so you can sign in.

Your email and password are case sensitive.

* denotes a mandatory field.

Member Login

Update my password

Lost Login

Not a member yet?

Update my profile

Rolling Stock - EN

Product Datasheets and Approvals

Rolling Stock - ENPrint summary for selected product(s)
Print
Compare two selected products
Compare
EN50264-2-1 Standard Wall 0.6/1.0V single core
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Standard wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits, electric heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI101, EI103
-40C to +90C EI102, EI104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-2-1 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-1 Standard Wall 1.8/3kV single core
Datasheet
Voltage Rating 1.8/3kV volts
Description Standard wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include auxilliary circuits at line voltage, traction circuits, electric heating.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI101, EI103
-40C to +90C EI102, EI104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-2-1 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-1 Standard Wall 1.8/3kV single core, sheathed
Datasheet
Voltage Rating 1.8/3kV volts
Description Standard wall single core, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include auxilliary circuits at line voltage, traction circuits, electric heating circuits on exposed trays.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-2-1 Table 3
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-1 Standard Wall 3.6/6kV single core, sheathed
Datasheet
Voltage Rating 3.6/6kV volts
Description Standard wall singlecore, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include auxilliary circuits at line voltage, traction circuits, electric heating circuits on exposed trays.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-2-1 Table 4
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-2 Standard Wall 0.3/0.5kV multicore
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Standard wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers
(see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-2-2 Standard Wall 0.3/0.5kV multicore, screened
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Standard wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers (see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-2-2 Standard Wall 0.6/1.0kV multicore
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Standard wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Tables 4,6,8
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-2 Standard Wall 0.6/1.0kV multicore, screened
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Standard wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Tables 5,7,9
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-1 Reduced Wall 0.6/1.0V single core
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Reduced wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits, electric heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI106, EI108
-40C to +90C EI107, EI109
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-3-1 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-1 Reduced Wall 1.8/3V single core
Datasheet
Voltage Rating 1.8/3kV volts
Description Reduced wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include power and heating circuits.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI106, EI108
-40C to +90C EI107, EI109
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-3-1 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagatio
EN50305 Toxicity
EN50264-3-1 Reduced Wall 1.8/3V single core, sheathed
Datasheet
Voltage Rating 1.8/3kV volts
Description Reduced wall single core, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include power and heating circuits.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-3-1 Table 3
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-1 Reduced Wall 3.6/6V single core, sheathed
Datasheet
Voltage Rating 3.6/6kV volts
Description Reduced wall single core, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include power and heating circuits.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-3-1 Table 4
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-2 Reduced Wall 0.3/0.5kV multicore
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Reduced wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers (see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-3-2 Reduced Wall 0.3/0.5kV multicore, screened
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Reduced wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers (see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-3-2 Reduced Wall 0.6/1.0kV multicore
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Reduced wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Tables 4,6,8
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-2 Reduced Wall 0.6/1.0kV multicore, screened
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Reduced wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Tables 5,7,9
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50306-2 Thin Wall 0.3/0.5kV single core
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits, internal wiring of equipment.
Construction Stranded tinned copper conductor, LFH insulation
Operating Temperature -25C to +105C
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification White
Sheath Colour N/A
Manufacturing Standard EN50306-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-3 Thin Wall 0.3/0.5kV single and multicore, screened
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall single core and multicore screened cables for use in rolling stock as fixed wiring or where there is limited flexing. Applications include control and monitoring circuits, interlocking circuits, indicating circuits, internal wiring of equipment.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screen, LFH sheath
Operating Temperature -25C to +90C S2
-40C to +105C S1
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-3 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, screen, std wall sheath class E
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, screened, multicore cables with standard wall sheaths for use in exposed situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screen, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 3 (E)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, screened, std wall sheath class P
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, screened, multicore cables with standard wall sheaths for use in protected situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screen, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 3 (P)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, std wall sheath class E
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall multicore cables with standard wall sheaths for use in exposed situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include control and monitoring circuits, interlocking circuits, indicating circuits, internal wiring run on exposed trays.
Construction Stranded tinned copper conductor, LFH insulation, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 1 (E)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, std wall sheath class P
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall multicore cables with standard wall sheaths for use in protected situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include control and monitoring circuits, interlocking circuits, indicating circuits, internal wiring of equipment.
Construction Stranded tinned copper conductor, LFH insulation, LFH sheath
Operating Temperature -25C to +90C S2
-40C to +105C S1
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 1 (P)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multipair, ind screen, std wall sheath class E
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, individually screened, multipair cables with standard wall sheaths for use in exposed situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screened pairs, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 5 (E)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multipair, ind screen, std wall sheath class P
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, individually screened, multipair cables with standard wall sheaths for use in protected situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screened pairs, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 5 (P)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 1.8/3kV single core
Datasheet
Voltage Rating 1.8/3kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation (optional braid)
Operating Temperature -40C to +120C tinned coppe
r -40C to +150C plain copper
Minimum Bending Radius 10x cable diameter
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50382-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 1.8/3kV single core, sheathed
Datasheet
Voltage Rating 1.8/3kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation, LFH sheath
Operating Temperature -25C to +120C EM105
-40C to +120C EM106
-40C to +150C EM107
Minimum Bending Radius 10x cable diameter
Core Identification White
Sheath Colour black
Manufacturing Standard EN50382-2 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 3.6/6kV single core
Datasheet
Voltage Rating 3.6/6kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation (optional braid)
Operating Temperature -40C to +120C tinned copper
-40C to +150C plain copper
Minimum Bending Radius 10x cable diameter
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50382-2 Table 3
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 3.6/6kV single core (class 6, enhanced insulation)
Datasheet
Voltage Rating 3.6/6kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction, power and inter coach power circuits.
Construction Flexible class 6 copper conductors, LFH Insulation (optional braid)
Operating Temperature -40C to +120C tinned copper
-40C to +150C plain copper
Minimum Bending Radius 10x cable diameter
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50382-2 Table 4
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 3.6/6kV single core, sheathed
Datasheet
Voltage Rating 3.6/6kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation, LFH sheath
Operating Temperature -25C to +120C EM105
-40C to +120C EM106
-40C to +150C EM107
Minimum Bending Radius 10x cable diameter
Core Identification White
Sheath Colour Black
Manufacturing Standard EN50382-2 Table 5
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.