G4726 (formerly EME-SP-14-026)
Datasheet
Voltage Rating 450/750 volts
Description Singlecore LSZH cable for LV power and dc traction supply.
Construction Stranded copper conductors, LSZH insulation
Operating Temperature -20degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Bn, Be, Bk, Gy, Gn/Yw, Rd, We
Sheath Colour N/A
Manufacturing Standard G4726
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G4727 (formerly EME-SP-14-027)
LUL
 Product Image
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Single and multicore LSZH armoured power cables
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, LSZH bedding, single core AWA 2 or more cores SWA, LSZH sheath.
Operating Temperature -20degC to +85degC
Minimum Bending Radius 8x cable diameter
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
Sheath Colour Black
Manufacturing Standard G4727
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
LSZH Medium Voltage 12.7/22kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P27.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 12.7/22kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P13.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core 12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 19/33kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P28.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 19/33kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P14
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 3.8/6.6 kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P24.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 3.8/6.6 kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P10.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 6.35/11kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P25.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 6.35/11kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P11.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 8.7/15kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P26.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 8.7/15kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P12.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LUL S1108 (formerly 1-108 & EME-SP-14-025) Track Feeder
LUL
Datasheet
Approval
Voltage Rating 750 volts
Description 500/630 and 935sqmm LFH track feeder cables. Now replaced by LUL Specification S1108 (formerly 1-108) and Metronet specification MR SE908. For use indoor or outdoor either as a power cable forming part of a DC traction supply within a substationand ending with connection to the traction conductor rail, or as a connector between two lengths of conductor rail. Can be laid unprotected over track ballast.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 8 x diameter
Sheath Colour Black with yellow stripe
Manufacturing Standard 1-108 (EME-SP-14-025)
NR/L2/ELP/40045 Point Heater Cables
Datasheet
Voltage Rating 300/500 volts
Description Cables fo use on electric point heating installations
Construction Flexible tinned copper, EPR insulation, heavy duty sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 8 x diameter
Core Identification 4 core Yw, Yw, Be, Be
8 core Yw, Yw, Be, Be, Bn, Bn, Bk, Bk
Sheath Colour Black
Manufacturing Standard NR/L2/ELP/40045
Emissions and
Flame Propagation
IEC60332
NR/PS/ELP/21101 (DC112) Track Feeder
Datasheet
Approval
Voltage Rating 750 volts
Description Traction cables for use on dc traction systems to provide the supply from traction substations and track paralleling huts to the conductor rails and negative cable connections and, where appropriate, bonding.
Construction Stranded tinned copper or aluminium conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 8 x diameter for copper
10x for aluminium
Sheath Colour Black
Manufacturing Standard NR/PS/ELP/21101
PVC Medium Voltage 12.7/22kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P22.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 12.7/22kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P8.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 19/33kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P23.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 19/33kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P9.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 3.8/6.6 kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P19.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 3.8/6.6 kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P5.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 6.35/11kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P20.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 6.35/11kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P6.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 8.7/15kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P21.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 8.7/15kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P7.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
SE260
Datasheet
Voltage Rating 1000 volts
Description Pigtail rail connection for underground and surface locations
Construction 16sqmm stranded plain or tinned copper wires, PVC or LSZH insulation, PVC or LSZH sheath.
Operating Temperature -25degC to +85degC
Minimum Bending Radius 3 x diameter
Core Identification white, others on request
Sheath Colour PVC grey
LSZH red or black
Manufacturing Standard SSL-SE-0260
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085 LSZH only
SE774
Datasheet
Voltage Rating 700 volts
Description Singlecore cables for equipment room signalling power supplies and earthing
Construction Stranded tinned copper conductors, LFH insulation
Operating Temperature -15C to +85C
Minimum Bending Radius 1 to 16sqmm 2 x cable diameter
35sqmm 3 x cable diameter
Core Identification N/A
Sheath Colour Bk, Yw or Gn/Yw
Manufacturing Standard SSL-SE-0774
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE882
Datasheet
Voltage Rating 1000 volts
Description 2 core AC signal main cable providing power from sub-stations to signalling equipment
Construction Stranded tinned copper conductors, 35sqmm or 70sqmm, thermoplastic LSZH insulation, thermoplastic LSZH sheath
Operating Temperature -15C to +90C
Minimum Bending Radius 6x cable diameter
Core Identification Bn/Be
Sheath Colour Yellow
Manufacturing Standard MR-SE-882
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE895
LUL
Datasheet
Voltage Rating 120 volts
Description LSZH track circuit feed cable
Construction 4sqmm stranded tinned copper wire, LSZH insulation, LSZH sheath.
Operating Temperature -15C to +85C
Minimum Bending Radius 2x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard SE895
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.