AEI Cables - Oil, Gas and Marine Low Voltage

logo

Login Help

Please enter your email address that you registered with. We will email you your password so you can sign in.

Your email and password are case sensitive.

* denotes a mandatory field.

Member Login

Update my password

Lost Login

Not a member yet?

Update my profile

Oil, Gas and Marine Low Voltage

Product Datasheets and Approvals

Oil, Gas and Marine Low VoltagePrint summary for selected product(s)
Print
Compare two selected products
Compare
0.6/1.0kV BS 6883 - Armoured
Datasheet
Approval
3D Model
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or multicore, LSZH bedding, single core TPBB or multicores GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or 1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS6883 Tables 20, 21, 22, 23, 24
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.6/1.0kV BS 6883 - Unarmoured
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single, two, three, four core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or 1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS6883 Tables 18,19
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
1.9/3.3kV BS 6883 - Armoured
Datasheet
Voltage Rating 1900/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS6883 Tables 30, 31
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
3.3/3.3kV BS 6883 - Armoured
Datasheet
Voltage Rating 3300/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS6883 Tables 32, 33
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.