Oil, Gas and Marine Instrumentation

Product Datasheets and Approvals

Oil, Gas and Marine InstrumentationPrint summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-pair Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 7, 8, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-pair Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 5, 6, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-quad Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually screened quads, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 14
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-quad Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened quads, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 13
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-triple Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 11, 12, 25,26
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-triple Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 9, 10, 22,23
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.