Defence Standard 61-12 Part 25 Print Compare
Table 11: Multicore (Collective Screen) 0.20mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 11
Table 12: Multicore (Collective Screen) 0.35mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore collectively screened LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 12
Table 13: Multicore (Collective Screen) 0.60mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 13
Table 14, 26: Multicore (Collective Screen) 1.00mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore collectively screened LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Table 14 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Table 26 (Power)
3 core be, bn, gn/yw
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 14, 26
Table 15: Multipair (Collective Screen) 0.35mm²
Datasheet
Voltage Rating
600 volts
Description
Multipair collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 15
Table 16: Multipair (Collective Screen) 1.00mm²
Datasheet
Voltage Rating
600 volts
Description
Multipair collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 16
Table 17: Multipair (Individual Screen) 0.35mm²
Datasheet
Voltage Rating
600 volts
Description
Multipair individually screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 17
Table 18: Multipair (Individual Screen) 1.00mm²
Datasheet
Voltage Rating
600 volts
Description
Multipair individually screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 18
Table 19: Multipair (Individual/Collective Screen) 0.35mm²
Datasheet
Voltage Rating
600 volts
Description
Multipair individually and collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 19
Table 20: Multitriple (Collective Screen) 0.35mm²
Datasheet
Voltage Rating
600 volts
Description
Multitriple collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multitriple cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Numbered triples.
Each triple rd/we/be
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 20
Table 27: Multicore (Collective Screen) 1.50mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore collectively screened LFH cables suitable for use in power applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Be, bn gn/yw
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 27
Table 28: Multicore (Collective Screen) 2.50mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore collectively screened LFH cables suitable for use in power applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
2 core bn, be
3 core bn, be, gn/yw
4 core bn, be, bk, gn/yw
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 28
Table 4: Multicore 0.20mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 4
Table 5: Multicore 0.35mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 5
Table 6, 22: Multicore 0.60mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Table 6 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Table 22 (Power)
3 core be, bn, gn/yw
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 6, 22
Table 7, 21, 23: Multicore 1.00mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Table 7 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Table 21 (Power)
2 core be, bn
Table 23(Power)
3 core be, bn, gn/yw
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 7, 21, 23
Table 8, 24: Multicore 1.50mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Table 8 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Table 24 (Power)
3 core be, bn, gn/yw
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 8, 24
Table 9, 25: Multicore 2.50mm²
Datasheet
Voltage Rating
600 volts
Description
Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction
Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature
-30degC to +105degC
Minimum Bending Radius
4x overall diameter fixed
10x overall diameter flexing
Core Identification
Table 9 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Table 25 (Power)
3 core be, bn, gn/yw
Lengths
100/500m or to order
Sheath Colour
Black
Manufacturing Standard
Def Stan 61-12 Part 25 Table 9, 25