AEI Cables - Defence Standard 02-527 (NES527)

logo

Login Help

Please enter your email address that you registered with. We will email you your password so you can sign in.

Your email and password are case sensitive.

* denotes a mandatory field.

Member Login

Update my password

Lost Login

Not a member yet?

Update my profile

Defence Standard 02-527 (NES527)

Product Datasheets and Approvals

Defence Standard 02-527 (NES527)Print summary for selected product(s)
Print
Compare two selected products
Compare
Table C10: Miniature Multipair/triple (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Miniature multipair and multitriple fire resistant cables, collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Miniature multipair and multitriple cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, pairs/triples layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 100m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C10
Fire Tests BS6387
Table C11: Miniature Multicore (Individual and Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Miniature multicore fire resistant cables, individually and collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Miniature multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, TCWB, cores layed up TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 100/250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C11
Fire Tests BS6387
Table C1: Single core
Datasheet
Voltage Rating 440 volts
Description Singlecore, fire resistant cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Singlecore stranded tinned copper conductor, silicone insulated, glass fibre braided (Type E) or silicone impregnated glass tape (Type T) insulation, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C1
Fire Tests BS6387
Table C2: Two & Three core
Datasheet
Voltage Rating 440 volts
Description Twin and three core, fire resistant cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Twin and three core cables, stranded tinned copper conductor, silicone insulated, glass fibre braided (Type E) or silicone impregnated glass tape (Type T) insulation, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C2
Fire Tests BS6387
Table C3: Multicore
Datasheet
Voltage Rating 440 volts
Description Multicore, fire resistant cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided (Type E) or silicone impregnated glass tape (Type T) insulation, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C3
Fire Tests BS6387
Table C4: Twin & Multicore
Datasheet
3D Model
Voltage Rating 440 volts
Description Multicore, fire resistant control cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C4
Fire Tests BS6387
Table C5: Multipair (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Multipair, fire resistant cables, collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, cores twinned and layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C5
Fire Tests BS6387
Table C6: Multicore (Individual Screen)
Datasheet
Voltage Rating 440 volts
Description Multicore fire resistant cables, individually screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, TCWB, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C6
Fire Tests BS6387
Table C7: Multipair (Individual Screen)
Datasheet
Voltage Rating 440 volts
Description Multipair fire resistant cables, individually screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, TCWB, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C7
Fire Tests BS6387
Table C8: Multicore (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Multicore fire resistant cables, collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C8
Fire Tests BS6387
Table C9: Miniature Multicore
Datasheet
Voltage Rating 440 volts
Description Miniature multicore fire resistant cables, unscreened or individually or collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Miniature multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, unscreened or individually or collectively screened, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 100m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C9
Fire Tests BS6387

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.