Table 11: Multicore (Collective Screen) 0.20mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 11
 
Def Stan 61-12 Part 25 Table 12Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 12: Multicore (Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 12
 
Def Stan 61-12 Part 25 Table 13Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 13: Multicore (Collective Screen) 0.60mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 13
 
Def Stan 61-12 Part 25 Table 14, 26Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 14, 26: Multicore (Collective Screen) 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 14 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 26 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 14, 26
 
Def Stan 61-12 Part 25 Table 15Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 15: Multipair (Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multipair collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 15
 
Def Stan 61-12 Part 25 Table 16Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 16: Multipair (Collective Screen) 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multipair collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 16
 
Def Stan 61-12 Part 25 Table 17Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 17: Multipair (Individual Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multipair individually screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 17
 
Def Stan 61-12 Part 25 Table 18Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 18: Multipair (Individual Screen) 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multipair individually screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 18
 
Def Stan 61-12 Part 25 Table 19Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 19: Multipair (Individual/Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multipair individually and collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 19
 
Def Stan 61-12 Part 25 Table 20Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 20: Multitriple (Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multitriple collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multitriple cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered triples.
Each triple rd/we/be
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 20
 
Def Stan 61-12 Part 25 Table 27Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 27: Multicore (Collective Screen) 1.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Be, bn gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 27
 
Def Stan 61-12 Part 25 Table 28Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 28: Multicore (Collective Screen) 2.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core bn, be
3 core bn, be, gn/yw
4 core bn, be, bk, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 28
 
Def Stan 61-12 Part 25 Table 4Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 4: Multicore 0.20mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 4
 
Def Stan 61-12 Part 25 Table 5Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 5: Multicore 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 5
 
Def Stan 61-12 Part 25 Table 6, 22Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 6, 22: Multicore 0.60mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 6 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 22 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 6, 22
 
Def Stan 61-12 Part 25 Table 7, 21, 23Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 7, 21, 23: Multicore 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 7 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 21 (Power)
2 core be, bn

Table 23(Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 7, 21, 23
 
Def Stan 61-12 Part 25 Table 8, 24Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 8, 24: Multicore 1.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 8 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 24 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 8, 24
 
Def Stan 61-12 Part 25 Table 9, 25Print summary for selected product(s)
Print
Compare two selected products
Compare
Table 9, 25: Multicore 2.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 9 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 25 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 9, 25

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.