BS 7917 Ships, Oil and Gas, Fire Resistant Instrumentation and Power Cables

Quality and safety are the hallmarks of our diverse range of products, which are designed and manufactured to the very highest standards such as ISO 9001 and approved by the leading approvals organisations nationally and internationally including BASEC, LPCB and Lloyds.

BS7917 Table 10, 11Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 7917 - Multi-triple Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened triples, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 10, 11
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request
Min temperature for installation is -15degC
 
BS7917 Table 12, 13Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 7917 - Multi-triple Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened triples, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 12, 13
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Table 14Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS7917 - Multi-quad Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually screened quads, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 14
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Table 15Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 7917 - Multi-quad Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually screened quads, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 15
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Table 6, 7Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 7917 - Multi-pair Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened pairs, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 6, 7
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Table 8, 9Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 7917 - Multi-pair Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened pairs, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 8, 9
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Tables 19, 20Print summary for selected product(s)
Print
Compare two selected products
Compare
0.6/1.0kV BS 7917 - Unarmoured
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, single, two, three, four core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or
1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS7917 Tables 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Tables 21, 22, 23, 24, 25Print summary for selected product(s)
Print
Compare two selected products
Compare
0.6/1.0kV BS 7917 - Armoured
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or multicore, LSZH bedding, single core TPBB or multicore GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or
1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS7917 Tables 21, 22, 23, 24, 25
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Tables 31, 32Print summary for selected product(s)
Print
Compare two selected products
Compare
1.9/3.3kV BS 7917 - Armoured
Datasheet
Voltage Rating 1900/3300 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS7917 Tables 31, 32
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS7917 Tables 33, 34Print summary for selected product(s)
Print
Compare two selected products
Compare
3.3/3.3kV BS 7917 - Armoured
Datasheet
Voltage Rating 3300/3300 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS7917 Tables 33, 34
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.