BS 6883 Ships, Oil and Gas, Instrumentation and Power Cables

Quality and safety are the hallmarks of our diverse range of products, which are designed and manufactured to the very highest standards such as ISO 9001 and approved by the leading approvals organisations nationally and internationally including BASEC, LPCB and Lloyds.

BS6883 Table 11, 12, 25,26Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-triple Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 11, 12, 25,26
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 13Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-quad Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened quads, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 13
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 14Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-quad Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually screened quads, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 14
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 37, 38Print summary for selected product(s)
Print
Compare two selected products
Compare
3.8/6.6kV BS 6883 - Armoured (Non radial field)
Datasheet
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 12x diameter
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 37, 38
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 39, 40Print summary for selected product(s)
Print
Compare two selected products
Compare
6.6/6.6kV BS 6883 - Armoured (Non radial field)
Datasheet
Voltage Rating 6600/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 12x diameter
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 39, 40
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 41, 42Print summary for selected product(s)
Print
Compare two selected products
Compare
6.35/11kV BS 6883 - Armoured (Non radial field)
Datasheet
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 12x diameter
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 41, 42
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 46, 47Print summary for selected product(s)
Print
Compare two selected products
Compare
3.8/6.6kV BS 6883 - Unarmoured (Radial field)
Datasheet
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 46, 47
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 48, 49Print summary for selected product(s)
Print
Compare two selected products
Compare
3.8/6.6kV BS 6883 - Armoured (Radial field)
Datasheet
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 48, 49
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 5, 6, 19, 20Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-pair Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 5, 6, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 50, 51Print summary for selected product(s)
Print
Compare two selected products
Compare
6.35/11kV BS 6883 - Unarmoured (Radial field)
Datasheet
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 50, 51
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 52, 53Print summary for selected product(s)
Print
Compare two selected products
Compare
6.35/11kV BS 6883 - Armoured (Radial field)
Datasheet
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 52, 53
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 54, 55Print summary for selected product(s)
Print
Compare two selected products
Compare
8.7/15kV BS 6883 - Unarmoured (Radial field)
Datasheet
Voltage Rating 8700/15000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 54, 55
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 56, 57Print summary for selected product(s)
Print
Compare two selected products
Compare
8.7/15kV BS 6883 - Armoured (Radial field)
Datasheet
Voltage Rating 8700/15000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 56, 57
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 7, 8, 19, 20Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-pair Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 7, 8, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Table 9, 10, 22,23Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-triple Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 9, 10, 22,23
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Tables 18,19Print summary for selected product(s)
Print
Compare two selected products
Compare
0.6/1.0kV BS 6883 - Unarmoured
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single, two, three, four core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or 1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS6883 Tables 18,19
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Tables 20, 21, 22, 23, 24Print summary for selected product(s)
Print
Compare two selected products
Compare
0.6/1.0kV BS 6883 - Armoured
Datasheet
Approval
3D Model
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or multicore, LSZH bedding, single core TPBB or multicores GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or 1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS6883 Tables 20, 21, 22, 23, 24
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Tables 30, 31Print summary for selected product(s)
Print
Compare two selected products
Compare
1.9/3.3kV BS 6883 - Armoured
Datasheet
Voltage Rating 1900/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS6883 Tables 30, 31
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
 
BS6883 Tables 32, 33Print summary for selected product(s)
Print
Compare two selected products
Compare
3.3/3.3kV BS 6883 - Armoured
Datasheet
Voltage Rating 3300/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS6883 Tables 32, 33
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.