OIL AND GAS
Product Datasheets and Approvals.
Fade
LSZH InstrumentationPrint
Select
Product
Compare
show/hide product data0.15/0.25kV Multi-pair Unarmoured
Close0.15/0.25kV Multi-pair Unarmoured
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS6883 Table 5, 6, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-pair Armoured
Close0.15/0.25kV Multi-pair Armoured
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS6883 Table 7, 8, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-triple Unarmoured
Close0.15/0.25kV Multi-triple Unarmoured
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS6883 Table 9, 10, 22,23
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-triple Armoured
Close0.15/0.25kV Multi-triple Armoured
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS6883 Table 11, 12, 25,26
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-quad Unarmoured
Close0.15/0.25kV Multi-quad Unarmoured
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened quads, layed up, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS6883 Table 13
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-quad Armoured
Close0.15/0.25kV Multi-quad Armoured
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually screened quads, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS6883 Table 14
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
 
Fire Resisting InstrumentationPrint
Select
Product
Compare
show/hide product data0.15/0.25kV Multi-pair Unarmoured
Close0.15/0.25kV Multi-pair Unarmoured
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened pairs, layed up, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS7917 Table 6, 7
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-pair Armoured
Close0.15/0.25kV Multi-pair Armoured
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened pairs, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS7917 Table 8, 9
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-triple Unarmoured
Close0.15/0.25kV Multi-triple Unarmoured
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened triples, layed up, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS7917 Table 10, 11
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-triple Armoured
Close0.15/0.25kV Multi-triple Armoured
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened triples, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS7917 Table 12, 13
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-quad Unarmoured
Close0.15/0.25kV Multi-quad Unarmoured
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually screened quads, layed up, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS7917 Table 14
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.15/0.25kV Multi-quad Armoured
Close0.15/0.25kV Multi-quad Armoured
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually screened quads, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
8x overall diameter
Core
Identification
white, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing
Standard
BS7917 Table 15
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
 
LSZH Low VoltagePrint
Select
Product
Compare
show/hide product data0.6/1.0kV Unarmoured
Close0.6/1.0kV Unarmoured
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single, two, three, four core, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 2 core Rd, Bk 3 core Rd, Yw, Be 4 core Rd, Yw, Be, Bk multicores white numbered
Sheath Colour black
Manufacturing
Standard
BS6883 Tables 18,19
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.6/1.0kV Armoured
Close0.6/1.0kV Armoured
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or multicore, LSZH bedding, single core TPBB or multicores GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 2 core Rd, Bk 3 core Rd, Yw, Be 4 core Rd, Yw, Be, Bk multicores white numbered
Sheath Colour black
Manufacturing
Standard
BS6883 Tables 20, 21, 22, 23, 24
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model 3D
show/hide product data1.9/3.3kV Armoured
Close1.9/3.3kV Armoured
Voltage Rating 1900/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour black
Manufacturing
Standard
BS6883 Tables 30, 31
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data3.3/3.3kV Armoured
Close3.3/3.3kV Armoured
Voltage Rating 3300/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour black
Manufacturing
Standard
BS6883 Tables 32, 33
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
 
Fire Resisting Low VoltagePrint
Select
Product
Compare
show/hide product data0.6/1.0kV Unarmoured
Close0.6/1.0kV Unarmoured
Voltage Rating 600/1000 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, single, two, three, four core, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 2 core Rd, Bk 3 core Rd, Yw, Be 4 core Rd, Yw, Be, Bk multicores white numbered
Sheath Colour black
Manufacturing
Standard
BS7917 Tables 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data0.6/1.0kV Armoured
Close0.6/1.0kV Armoured
Voltage Rating 600/1000 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or multicore, LSZH bedding, single core TPBB or multicore GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 2 core Rd, Bk 3 core Rd, Yw, Be 4 core Rd, Yw, Be, Bk multicores white numbered
Sheath Colour black
Manufacturing
Standard
BS7917 Tables 21, 22, 23, 24, 25
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) Approval1
3D Cable Model N/A
show/hide product data1.9/3.3kV Armoured
Close1.9/3.3kV Armoured
Voltage Rating 1900/3300 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour black
Manufacturing
Standard
BS7917 Tables 31, 32
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data3.3/3.3kV Armoured
Close3.3/3.3kV Armoured
Voltage Rating 3300/3300 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
4x diameter for <25mm 6x diameter for >25mm
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour black
Manufacturing
Standard
BS7917 Tables 33, 34
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
 
LSZH Medium VoltagePrint
Select
Product
Compare
show/hide product data3.8/6.6kV Armoured (Non radial field)
Close3.8/6.6kV Armoured (Non radial field)
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
12x diameter
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 37, 38
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data6.6/6.6kV Armoured (Non radial field)
Close6.6/6.6kV Armoured (Non radial field)
Voltage Rating 6600/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
12x diameter
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 39, 40
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data6.35/11kV Armoured (Non radial field)
Close6.35/11kV Armoured (Non radial field)
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
12x diameter
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 41, 42
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data3.8/6.6kV Unarmoured (Radial field)
Close3.8/6.6kV Unarmoured (Radial field)
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
20x diameter single core 15x diameter three core
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 46, 47
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data6.35/11kV Unarmoured (Radial field)
Close6.35/11kV Unarmoured (Radial field)
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
20x diameter single core 15x diameter three core
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 50, 51
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data8.7/15kV Unarmoured (Radial field)
Close8.7/15kV Unarmoured (Radial field)
Voltage Rating 8700/15000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
20x diameter single core 15x diameter three core
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 54, 55
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data3.8/6.6kV Armoured (Radial field)
Close3.8/6.6kV Armoured (Radial field)
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
20x diameter single core 15x diameter three core
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 48, 49
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data6.35/11kV Armoured (Radial field)
Close6.35/11kV Armoured (Radial field)
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
20x diameter single core 15x diameter three core
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 52, 53
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A
show/hide product data8.7/15kV Armoured (Radial field)
Close8.7/15kV Armoured (Radial field)
Voltage Rating 8700/15000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating
Temperature
-30degC to +85degC
Minimum
Bending Radius
20x diameter single core 15x diameter three core
Core
Identification
1 core Bk 3 core Rd, Yw, Be
Sheath Colour red
Manufacturing
Standard
BS6883 Table 56, 57
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions
and Flame
Propagation
BS4066 (IEC60332) Flame propagation BS7622 (IEC601034) Smoke Emission BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternatice SW2 CSP sheath available on request. Min temperature for installation is -15degC
Product Datasheet Datasheet
Product Approval(s) N/A
3D Cable Model N/A

Compare Selected Products

Print Selected Product Data
navigation tips
Product detail can be viewed by clicking on the desired product type.

Two products can be compared by ticking their boxes and then clicking here or on the 'Compare' link below the list.

After selecting one or more products to be printed, click here or on the 'Print' link below the list.

When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.
cable sizing wizard
Try our unique free online cable calculator to select the right product for all your applications
Cable Sizing Wizard